276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
2 hr rated roof assembly.
Stc description system rating test no.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
All new fire rated roof ceiling assembly files.
Fire rated construction acoustical performance partition applications fire detail physical data description test no.
Gypsum panel end joints located midway between continuous channels and attached to additional pieces of channels 54 1372 mm long with screws 12 305 mm o c.
Ul p533 roof ceiling one layer 5 8 15 9 mm fire shield c ga rc 2603 wallboard attached to 1 2 12 7 mm resilient furring channel spaced 12 o c.
These listings are short summaries to serve as a.
V337 2 hour interior wall assembly ul design no.
Urb concealed grid system and tile.
1 2 12 7 mm toughrock fireguard c or 1 2 12 7 mm densarmor plus fireguard c gypsum panel applied perpendicular to resilient channels 24 610 mm o c.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
2 hour exterior wall assembly ul design no.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
Wd stud 2 layers 5 8 sheetrock brand gypsum n a j panels firecode core outside both sides 5 8 sheetrock brand gypsum panels firecode core inside both sides 2 rows 2 x 4 24 o c base layer.
With 1 2 wood structural panels with.
Lp flameblock fire rated osb sheathing is a component of the following code compliant fire rated assemblies.
Shaft wall limiting heights spans.
Concrete with cellular steel 3 hr.
With 1 25 mm type s drywall screws 12 305 mm o c.
Fire rated wall floor and ceiling assemblies provide the necessary fire and smoke barriers to create compartmentalization during a fire safeguarding against the spread of fire and smoke within a building or to and from a building.
6 usg fire resistant assemblies test certiļ¬cation test conditions and fire and sound tested assemblies listed in this selector are based on characteristics properties and performance certificationof materials and systems obtained under controlled test conditions as set forth in the appropriate astm standard in effect at the time of test.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
Ibc table 721 3 item 21 1 1 describes a single prescriptive 1 hour rated floor or roof assembly that includes wood trusses.
Screw fastened perpendicular to lower chord of wood trusses of 2 x 4 38 mm x 89 mm.
Find usg product specific cad and revit files.
Gypsum wallboard roof ceilings wood framing pitched roof truss 11 1 hr.